Epoxy Floor Screeds

DESCRIPTION

SYSFLOOR 581 is a three component Solvent free Epoxy Floor System. The finished floor provides a hard wearing which is chemical resistant, Seamless and extremely easy to clean & which is non-toxic. Can be laid in various thickness from 2 mm to 4 mm.

ADVANTAGES

• Anti — Skid in nature.
• Excellent resistance to Sea water and sewage water.
• Hygienic in Nature.
• Durable.
• Low maintenance costs.
• Non -shrink in nature.
• Can withstand temperature change.
• Available in Various attractive Colours.

AREAS OF APPLICATION

SYSFLOOR 581 is applied in areas like Nuclear Power Plants, Pharma & Bulk Industries, Laboratories, Food processing units, Distelliers, Hospital & Computer Clean rooms, Industrial units, and wherever food grade hygienic dust free floor is required.

CHEMICAL RESISTANCE CHART

SYSFLOOR 581 is resistant to various wide range of Chemicals. Data is available on request.

PROPERTIES
Pot Life:30 Minutes at 30 degrees Centigrade.
Initial Cure:24 Hours.
Final Cure:7 days at 30 degrees Centigrade.
Interval between Coats:24 Hours.
Compressive Strength:55 N/mm2.
Flexural Strength:34 N/mm2.
Tensile Strength:16 N/mm2.
Impact resistance:4 Kg/m.
METHOD OF USAGE
SURFACE PREPARATION

The Surface should be cleaned, dried, and free from any sort of loose particles. Concrete surface must be free from laitance and it can be removed from sand blasting. The surface must not contain a moisture content more than 4%. The surface has to be subjected to acid etching by using SYSCONS range of cleaning agents followed by washing with clean water.

PRIMING

For Cementitious surfaces SYSFLOOR 584 has to be used. The mixing of both Resin and Hardener has to be done by using Mechanical stirrer in order to disperse any sort of settlement. The contents of Hardener has to be poured in to the Base Resin and the mixing has to be done for at least three minutes to get an Homogeneous mixture. The coated surface has to be kept for Self cure for a period of 24 Hours.

MIXING OF 581

The Pre -weighed packs of SYSFLOOR 581 has to be mixed for about 3 to 4 minutes with a low speed mechanical mixer of 300 to 350 rpm. The mixing has to be done till we observe an homogeneous colour. Solvents or thinners should not be added.

LAYING OF SYSFLOOR 581

The mixed material is poured on to the Primed surface and spread to the required thickness with a steel trowel and immediately after spreading, the floor should be firmly rolled with a spiked nylon roller to help release any entrapped air in the material and help any slight trowel marks.

COVERAGE:

The coverage of SYSFLOOR 581 will be around 4 Sq.mtrs per Standard Pack of 14 Kgs. for 2 mm thickness.

CLEANING:

Clean all tools and equipment with Cleaning agents orAcetone immediately after the use.

SUPPLY:

14 Kg Standard Pack.

SHELF LIFE:

12 Months from the date of the Manufacture.

PRECAUTIONS

SYSFLOOR 581 should be applied with gloves and care should be taken to see that it does not fall on the eyes. Splashes on to the skin has to be removed immediately with a resin removal cream and medical advice has to be taken.

TECHNICAL SUPPORT

Technical information and guidance regarding SYSPLAST range of Admixtures, SYSGROUT range of Cementitious and Epoxy Grouting Systems, can be obtained from the technical cell of SYSCONS.

NOTE

Information in this Technical data sheet is to the best of our knowledge true and Accurate. However such conditions under which our products may be used or obtained beyond our control, recommendations are made without Warranty or Guarantee.

DESCRIPTION

SYSFLOOR 582 is a three component Solvent free Epoxy Resin Floor System. The finished floor provides a hard wearing which is chemical and abrasion resistant, Seamless and which is non-toxic. Can be laid in various thickness from 3 mm to 5 mm.

ADVANTAGES

• Anti —Skid in nature.
• Easily applied as a Universal Industrial Screed.
• Excellent Load Bearing.
• Durable.
• Low Maintenance costs.
• Abrasion Resistant & Chemical Resistant.
• Can also be used for repairs to Floors etc.

AREAS OF APPLICATION

SYSFLOOR 582 is applied in areas like Chemical Industries, Heavy Industries, Workshops, Machine Shops, Ramps and wherever high Wear & Tear resistance & Chemical Resistance floor is required.
Specially made for Engineering Units, Dairies, Refineries, Battery Rooms, Food Processing Units & Breweries.

CHEMICAL RESISTANCE CHART

SYSFLOOR 582 is resistant to various wide range of Chemicals. Data is available on request.

PROPERTIES
Base:Epoxy resin.
Pot Life:20 to 30 Minutes at 30 degrees Centigrade.
Final Cure:7 days at 30 degrees Centigrade.
Foot traffic:12 to 18 Hours at 30 degrees Centigrade.
Compressive Strength:70 N/mm2 after 7 Days.
Flexural Strength:32 N/mm2.
Tensile Strength:15 N/mm2.
METHOD OF USAGE

Surface Preparation The Surface should be clean, dry and free from any sort of loose particles. Concrete surface must be free from laitance and it can be removed from sand blasting. The surface must not contain a moisture content more than 4%. The surface has to be subjected to acid etching by using SYSCONS range of cleaning agents followed by washing with clean water.

PRIMING

For Cementitious surfaces SYSFLOOR 585 has to be used. The mixing of both Resin and Hardener has to be done by using Mechanical stirrer in order to disperse any sort of settlement. The contents of Hardener has to be poured in to the Base Resin and the mixing has to be done for at least three minutes to get an Homogeneous mixture. The primed surface has to be kept for Self cure for a period of 24 Hours.

MIXING OF SYSFLOOR 582

The Pre -weighed packs of SYSFLOOR 582 has to be mixed for about 3 to 4 minutes with a low speed mechanical mixer of 300 to 350 rpm. to get an homogeneous mix. Solvents or thinners should not be added.

LAYING OF SYSFLOOR 582

The mixed material is laid on to the Primed surface and spread to the required thickness with a steel trowel . The Material should be compacted & finished with a steel float for desired thickness. This may also be power trowelled with a plastic coated disc.

COVERAGE

The coverage of SYSFLOOR 582 will be around
At 3 mm thickness :   2.2 Sq.mtrs per Standard Pack of 16 Kgs .
At 5 mm thickness :   1.4 Sq.mtrs per Standard Pack of 16 Kgs .

CLEANING:

Clean all tools and equipment with Cleaning agents orAcetone immediately after the use.

SUPPLY:

16Kg Standard Pack.

SHELF LIFE:

12 Months from the date of the Manufacture.

PRECAUTIONS

SYSFLOOR 582 should be applied with gloves and care should be taken to see that it does not fall on the eyes. Splashes on to the skin have to be removed immediately with a resin removal cream and medical advice has to be taken.

TECHNICAL SUPPORT

Technical information and guidance regarding SYSPLAST range of Admixtures, SYSGROUT range of Cementitious and Epoxy Grouting Systems, can be obtained from the technical cell of SYSCONS.

NOTE

Information in this Technical data sheet is to the best of our knowledge true and Accurate. However such conditions under which our products may be used or obtained beyond our control, recommendations are made without Warranty or Guarantee.

DESCRIPTION

SYSFLOOR 583 is a three component Solvent free Epoxy Floor System. The finished floor provides a hard wearing which is chemical resistant, Seamless and extremely easy to clean & which is non-toxic. Can be laid in various thickness from 3 mm to 5 mm.

ADVANTAGES

• Anti —Skid in nature.
• Easily applied as a Universal Industrial Screed.
• Excellent Load Bearing.
• Durable.
• Low Maintenance costs.
• Abrasion Resistant & Chemical Resistant.
• Can also be used for repairs to Floors etc.

AREAS OF APPLICATION

SYSFLOOR 583 is applied in areas like Chemical Industries, Heavy Industries, Ramps and wherever high wear & tear resistance & Chemical Resistance floor is required.
Specially made for Engineering Units, Dairies, Refineries, Battery Rooms, Food Processing Units & Breweries. Can also be used as a repair Mortar.

CHEMICAL RESISTANCE CHART

SYSFLOOR 583 is resistant to various wide range of Chemicals. Data is available on request.

PROPERTIES
Base:Epoxy resin.
Pot Life:20 to 30 Minutes at 30 degrees Centigrade.
Final Cure:7 days at 30 degrees Centigrade.
Foot traffic:16 to 24 Hours at 30 degrees Centigrade.
Compressive Strength:65 N/mm2 after 7 Days.
Flexural Strength:28 N/mm2.
Tensile Strength:12 N/mm2.
METHOD OF USAGE
SURFACE PREPARATION

The Surface should be cleaned, dried, and free from any sort of loose particles. Concrete surface must be free from laitance and it can be removed from sand blasting. The surface must not contain a moisture content more than 4%. The surface has to be subjected to acid etching by using SYSCONS range of cleaning agents followed by washing with clean water.

PRIMING

For Cementitious surfaces SYSFLOOR 585 has to be used. The mixing of both Resin and Hardener has to be done by using Mechanical stirrer in order to disperse any sort of settlement. The contents of Hardener has to be poured in to the Base Resin and the mixing has to be done for at least three minutes to get an Homogeneous mixture. The surface has to be kept for Self cure for a period of 24 Hours.

MIXING OF SYSFLOOR 583

The Pre -weighed packs of SYSFLOOR 583 has to be mixed for about 3 to 4 minutes with a low speed mechanical mixer of 300 to 350 rpm. to get an homogeneous mix. Solvents or thinners should not be added.

LAYING OF SYSFLOOR 583

The mixed material is laid on to the Primed surface and spread to the required thickness with a steel trowel. The Material should be compacted & finished with a steel float for desired thickness. This may also be power trowelled with a plastic coated disc.

COVERAGE

The coverage of SYSFLOOR 583 will be around
At 3 mm thickness :   2.2 Sq. mtrs per Standard Pack of 16 Kgs .
At 5 mm thickness :   1.4 Sq. mtrs per Standard Pack of 16 Kgs .

CLEANING:

Clean all tools and equipment with Cleaning agents orAcetone immediately after the use.

SUPPLY:

16 Kg Standard Pack.

SHELF LIFE:

12 Months from the date of the Manufacture.

PRECAUTIONS

SYSFLOOR 583 should be applied with gloves and care should be taken to see that it does not fall on the eyes. 
Splashes on to the skin have to be removed immediately with a resin removal cream and medical advice has to be taken.

TECHNICAL SUPPORT

Technical information and guidance regarding SYSPLAST range of Admixtures, SYSGROUT range of Cementitious and Epoxy Grouting Systems, can be obtained from the technical cell of SYSCONS.

NOTE

Information in this Technical data sheet is to the best of our knowledge true and Accurate. However such conditions under which our products may be used or obtained beyond our control, recommendations are made without Warranty or Guarantee.